Hantek MSO5202D - 2-Channel Mixed Signal 200MHz Oscilloscope

Special Order Item - 1 to 2 weeks - Please call for lead time

Hantek MSO5202D is a 2-channel Mixed Signal 200MHz oscilloscope. With the record length of up to 1M, this benchtop scope provides all the great features like a 7 inch WVGA (800x480) crisp color display, 1GS/s real-time sample rate, a huge range of auto measurements and multiple math functions (including FFT), all at an affordable price. Being official Australian Distributor, all of the units come with Australian w...

Availability: In stock

$995.00
Qty:

Hantek MSO5202D is a 2-channel Mixed Signal 200MHz oscilloscope. With the record length of up to 1M, this benchtop scope provides all the great features like a 7 inch WVGA (800x480) crisp color display, 1GS/s real-time sample rate, a huge range of auto measurements and multiple math functions (including FFT), all at an affordable price.

Being official Australian Distributor, all of the units come with Australian warranty.

Key Features:

  • 200MHz bandwidth
  • 1GSa/s Real Time sample rate
  • Large (7.0-inch) color display,WVGA(800x480)
  • Record length up to 1M
  • Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
  • USB connectivity
  • Multiple automatic measurements
  • Four math functions (including FFT)
  • VGA Optional

Model

MSO5202D

Acquisition

Sample Rate

Real-Time Sample: 1GS/s
Equivalent Sample: 50GS/s

Acquisition Modes

 

Normal

Normal data only

Peak Detect

High-frequency and random glitch capture

Average

Waveform Average, selectable 4,8,16,32,64,128

Inputs

Inputs Coupling

AC, DC, GND

Inputs Impendence

1MΩ±2% ‖20pF±3pF

Probe Attenuation

1X, 10X

Supported Probe Attenuation Factor

1X, 10X, 100X, 1000X

Maximum Input Voltage

CAT I and CAT II: 300VRMS (10×), Installation Category;
CAT III: 150VRMS (1×);
Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.

Horizontal

Sample Rate Range

500MS/s--1GS/s

Waveform Interpolation

(sin x)/x

Record Length

1M

SEC/DIV Range

2ns/div to 40s/div, 

Sample Rate and
Delay Time Accuracy

±50ppm(at over any ≥1ms time interval)

Position Range

2ns/div to 10ns/div; 
(-4div x s/div) to 20ms;

Delta Time Measurement Accuracy 
(Full Bandwidth)

Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
Sample interval = s/div ÷ 200

Vertical System

Vertical Resolution

8-bit resolution, all channel sampled simultaneously

Position Range

2mV/div to 10V/div

Bandwidth

200MHz

Rise Time at BNC( typical)

1.8ns

Analog Bandwidth in
Normal and Average
modes at BNC or with probe, DC Coupled

2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V
500mV/div to 2V/div, ±40V; 5V/div, ±50V

Math

+, -, *, /, FFT

Bandwidth Limit

20MHz

Low Frequency Response (-3db)

≤10Hz at BNC

DC Gain Accuracy

±3% for Normal or Average acquisition mode, 10V/div to 10mV/div;
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div

DC Measurement Accuracy, 
Average Acquisition Mode

When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; 
When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div

Volts Measurement Repeatability, 
Average Acquisition Mode

Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions

Trigger System

Trigger Types

Edge, Video, Pulse, Slope, Over time, Alternative

Trigger Source

CH1, CH2, EXT, EXT/5, AC Line

Trigger Modes

Auto, Normal, Single

Coupling Type

DC, AC, Noise Reject, HF Reject, LF Reject

Trigger Sensitivity
(Edge Trigger Type)

DC(CH1,CH2):
1div from DC to 10MHz;1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz;      
AC: Attenuates signals below 10Hz           
HF Reject: Attenuates signals above 80KHz; 
LF Reject: Same as the DC-coupled limits for frequencies above 150KHz; attenuates signals below 150KHz

Trigger Level Range

CH1/CH2: ±8 divisions from center of screen; 
EXT: ±1.2V;
EXT/5:±6V

Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns

CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
EXT: ± (6% of setting + 40mV);
EXT/5: ± (6% of setting + 200mV);

Set Level to 50%(typical)

Operates with input signals ≥50Hz

Video Trigger

 

Video Trigger Type 

CH1, CH2: Peak-to-peak amplitude of 2 divisions;
EXT: 400mV;
EXT/5: 2V

Signal Formats and Field Rates, Video Trigger Type

Supports NTSC, PAL and SECAM broadcast systems for any field or any line

Holdoff Range

100ns ~ 10s

Pulse Width Trigger

 

Pulse Width Trigger Mode

Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse

Pulse Width Trigger Point

Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width

Pulse Width Range

20ns ~ 10s

Slope Trigger

 

Slope Trigger Mode

Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope

Slope Trigger Point

Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.

Time Range

20ns ~ 10s

Overtime Trigger

 

Over Time Mode

Rising edge or Falling edge

Time Range

20ns ~ 10s

Alternative Trigger

 

Trigger on CH1

Internal Trigger: Edge, Pulse Width, Video, Slope

Trigger on CH2

Internal Trigger: Edge, Pulse Width, Video, Slope

Trigger Frequency Counter

 

Readout Resolution

6 digits

Accuracy (typical)

±30ppm (including all frequency reference errors and ±1 count errors)

Frequency Range

AC coupled, from 4Hz minimum to rated bandwidth

Signal Source

Pulse Width or Edge Trigger modes: all available trigger sources
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode: The Frequency Counter does not work.

Measurement

Cursor Measurement

Voltage difference between cursors: △V
Time difference between cursors: △T
Reciprocal of △T in Hertz (1/ΔT)

Auto Measuerment

Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF

Logic Analyzer Specifications

Channels

16 Channels

Max. Input Impendence

200K(C=10p)

Input Voltage Range

-60V~60V

Logic Threshold Range

-8V~8V

Max. Sample Rate

500MHz

 Compatible Input

TTL, CMOS, ECL

Sample Depth

512K

Trigger

 

Edge Trigger

D0-D15 select slope (rising or falling edge)

Pulse Width

D0-D15 select pulse polarity (positive or negative pulse), trigger when (=, ≠, >, <), trigger pulse width

Code-type

D0-D15 select code-type (H, L, X)

Duration

D0-D15 select persist time and trigger when (data terminate, data start, and data delay)

Queue

D0-D15 select specific data index (0-3) and code-type (H, L, X)

Repeat

D0-D15 select code-type (H, L, X) and repeat times

General Features

Display

 

Display Type

7 inch 64K color TFT (diagonal liquid crystal)

Display Resolution

800 horizontal by 480 vertical pixels

Display Contrast

Adjustable (16 gears) with the progress bar

Probe Compensator Output

 

Output Voltage( typical)

About 5Vpp into ≥1MΩ load

Frequency(typical)

1kHz

Power Supply

 

Supply Voltage

100-120VACRMS(±10%), 45Hz to 440Hz, CATⅡ
120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡ

Power Consumption

<30W

Fuse

2A, T rating, 250V

Environmental

 

Temperature

Operating: 32℉ to 122℉ (0℃ to 50℃);
Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃)

Cooling Method

Convection

Humidity

+104℉ or below (+40℃ or below): ≤90% relative humidity;
106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity

Altitude

Operating: Below 3,000m (10,000 feet);
Nonoperaring: Below 15,000m(50,000 feet)

Size & Weight

 

Size

385mm x 200mm x 245mm

Weight

2.08KG(without Packing)

 

How do you rate this product?

  1 star 2 stars 3 stars 4 stars 5 stars
Value
Quality
Price

Write your own review

Test Equipment


Test Equipment has always been proud of being one of the most progressive specialist suppliers of test and measurement equipment. Australian owned and operated by experienced engineers, we offer extensive product and application knowledge as well as quality service, which translates into a seamless experience when you procure your test and measurement instruments from us.


We started as a small business, fueled by the knowledge that we could make a positive impact and have come a long way since our inception, growing a small range of products into a full range of hundreds of products from some of the most respected brands in the industry such as AEMC, FLIR Systems, Kyoritsu, Megger and Testrix Systems. We now cater for a massive number of clientele from all types of industries including electrical contractors, utility companies, engineering businesses and large corporations as well as a large number of local, and state government departments. We now serve the whole of Australia with various instrumentation including cable & pipe locators, drain, sewer & pipe inspection cameras, ground penetrating radar, thermal imaging equipment, power quality equipment and a whole range of industrial test instruments such as low resistance testers, insulation resistance testers and ground resistance testers.


At Test Equipment, we have a wide variety of payment options for ease of purchasing, including ZIP PAY, EFTPOS and bank deposit and we offer fast courier shipping to all parts of Australia because we understand that time is money.


Browse through our website, or search online for the product you need, or feel free to call us if you need any help or advice.


Popular Test Equipment